Resources
White papers
Technical papers written by GeoAxon on ambient noise, attenuation and audiometric standards.

Expert Guidance on SANS 10083:2023 and its Implications for Boothless Audiometry with Kuduwave Technology
Abstract This technical report provides an evidence-based interpretation of the South African National Standard SANS 10083:2023 for occupational health professionals using the GeoAxon Kuduwave audiometer. It reaffirms that the standard has consistently been performance-based, requiring a verifiably
Read more
Validity of Automated Threshold Audiometry – A Systematic Review and Meta-Analysis
Abstract Objectives: A systematic literature review and meta-analysis on the validity (test–retest reliability and accuracy) of automated threshold audiometry compared with the gold standard of manual threshold audiometry was conducted. Design: A systematic literature review was completed in peer-re
Read more
Mobile Hearing Testing – The Challenge to Stay SABS Compliant (3 Part Series)
Part 1 When conducting hearing tests in a multitude of environments, e.g. factories and mines, it can, at times, be very challenging to confirm that the room or booth where the hearing tests will be conducted, is a quiet enough environment, according to SABS requirements. This article provides guid
Read more
The GeoAxon Kuduwave – A Validated Type 1 Clinical Audiometer for Comprehensive Diagnostic Assessment
Under review
Abstract This white paper aims to establish the GeoAxon Kuduwave (Prime, Pro, and Ultra models) as a Type 1 Clinical Audiometer, compliant with stringent international standards including IEC 60645-1 for pure-tone audiometry and IEC 60645-5 for immittance audiometry (Ultra model). It details the
Read more
A Scientific Critique of SANS 10083:2023 Section 15.1.2.3 Note 1: Rectifying an Impediment to Advanced Hearing Conservation Practices
Opinion
Abstract This white paper critiques Note 1 of Section 15.1.2.3 in the South African National Standard SANS 10083:2023, a standard for occupational noise and hearing conservation. This recently added note implies that if the sound-blocking capability (attenuation) of an audiometric device cannot be e
Read more
The Psychoacoustic Check: A Preferred Method for Audiometric Room Quietness Certification in South African Occupational Health
Abstract This white paper advocates for the adoption of an Psychoacoustic Check as the preferred, scientifically robust, and practical method for verifying audiometric room quietness in South African occupational health settings. Traditional physical sound level measurements (e.g., SANS 10182) for ro
Read more
A Comparative Analysis of Attenuation and Maximum Permissible Ambient Noise Levels for Audiometric Headsets
Abstract The accuracy of audiometric testing is fundamentally reliant on controlling ambient noise to prevent the masking of test stimuli. Various audiometric transducers, including supra-aural, circumaural, and insert earphones, as well as integrated headset systems, offer differing levels of passi
Read more
Determining OSHA-Compliant Maximum Permissible Ambient Noise Levels (MPANLs) for the Kuduwave Audiometer (Utilizing Foam Eartips)
Abstract: This white paper investigates the determination of OSHA-compliant Maximum Permissible Ambient Noise Levels (MPANLs) for the Kuduwave audiometer when used with foam eartips. It reviews OSHA’s baseline MPANLs (29 CFR 1910.95 Appendix D, Table D-1) and the more current ANSI S3.1-1999 (R2018)
Read more
Sound Attenuation in Audiometric Testing: A Review of Single-Walled Booths and Boothless Technologies for Occupational Hearing Screening
Abstract This white paper investigates the sound attenuation performance of typical single-walled, small audiometric test booths and an emerging boothless audiometry system (Kuduwave), specifically focusing on the 125-8000 Hz frequency range critical for comprehensive occupational hearing screening.
Read more
Advancing Audiometric Precision: Mastering Kuduwave’s SPHLin-ear with Standardised MPANL Correction Factors
Abstract Background: Ambient noise presents a persistent challenge to the accuracy of audiometric evaluations, particularly in settings outside traditional sound-attenuating booths. The Kuduwave audiometer is engineered to address this challenge through a sophisticated real-time ambient noise monito
Read more
Establishing Maximum Permissible Ambient Noise Levels for the Kuduwave Audiometer: A Guide for Clinical, Research, and Proposed Unified Global Applications
Abstract Background: The accuracy of audiometric testing is critically dependent on a controlled acoustic environment to prevent ambient noise from masking test stimuli. Traditional sound-treated booths, while effective, present limitations in cost, portability, and accessibility. The Kuduwave audio
Read moreSee the Kuduwave in your own practice