Resources
Blog
News, research summaries, white papers and stories about hearing care beyond the booth.

Remote Telehealth Hearing Assessment in a Rural Community – A Validation Study
Abstract The global need for increased hearing health care currently far exceeds the capacity for delivering these services, especially in developing countries where the ratio of audiologists to the population is often less than one per every million. The imbalance is further compounded by the requi
Read more
Revolutionizing Healthcare in India: The Untamed Impact of the GeoAxon Kuduwave
India isn’t just transforming hearing healthcare; it’s blazing a trail with game-changing solutions like the GeoAxon Kuduwave. We’re talking about bringing top-tier care right to your doorstep, even if your doorstep is in the most remote, off-the-grid village. Let’s be real: getting quality healthca
Read more
Validity of Automated Threshold Audiometry – A Systematic Review and Meta-Analysis
Abstract Objectives: A systematic literature review and meta-analysis on the validity (test–retest reliability and accuracy) of automated threshold audiometry compared with the gold standard of manual threshold audiometry was conducted. Design: A systematic literature review was completed in peer-re
Read more
Mobile Hearing Testing – The Challenge to Stay SABS Compliant (3 Part Series)
Part 1 When conducting hearing tests in a multitude of environments, e.g. factories and mines, it can, at times, be very challenging to confirm that the room or booth where the hearing tests will be conducted, is a quiet enough environment, according to SABS requirements. This article provides guid
Read more
The GeoAxon Kuduwave – A Validated Type 1 Clinical Audiometer for Comprehensive Diagnostic Assessment
Under review
Abstract This white paper aims to establish the GeoAxon Kuduwave (Prime, Pro, and Ultra models) as a Type 1 Clinical Audiometer, compliant with stringent international standards including IEC 60645-1 for pure-tone audiometry and IEC 60645-5 for immittance audiometry (Ultra model). It details the
Read more
Accuracy of Remote Hearing Assessment in Rural Community
Abstract Background: This study determined the accuracy of pure tone air conduction (AC) thresholds obtained using a synchronous telemedicine approach without a sound booth in a rural South African community. The global need for increased hearing healthcare currently far exceeds the capacity for del
Read more
Ambient Noise Impact On Accuracy Of Automated Audiometry
Abstract Objective: The aim of this study was to determine the effect of ambient noise on the accuracy of thresholds obtained using the KUDUwave portable clinical audiometer as compared to those obtained using a GSI-61 clinical audiometer in a sound booth. Design: Pure-tone air conduction thresholds
Read more
Diagnostic Pure-Tone Audiometry In Schools: Mobile Testing Without A Sound-Treated Environment
Abstract Purpose: To validate diagnostic pure-tone audiometry in schools without a sound-treated environment using an audiometer that incorporates insert earphones covered by circumaural earcups and real-time environmental noise monitoring. Research Design: A within-subject repeated measures design
Read more
Validity Of Diagnostic Pure-Tone Audiometry Using A Portable Computerised Audiometer Outside Of A Sound-Treated Environment
Abstract It is estimated that 10% of the global population is impaired to a significant degree by a decrease in hearing sensitivity. With the greatest proportion of these persons residing in developing countries where communities are grossly underserved, it is incumbent on hearing healthcare profess
Read more
Intercontinental Hearing Assessment – A Study in Tele-Audiology
Abstract We evaluated the validity of remote pure tone audiometric testing conducted from North America on subjects in South Africa. Desktop-sharing computer software was used to control an audiometer in Pretoria from Dallas, and PC-based videoconferencing was employed for clinician and subject comm
Read more
One-eartip solution for pure-tone audiometry and acoustic immittance measurements: using insert earphone with an immittance probe ear tip
Abstract Objective Two consecutive studies sought to determine the (1) Equivalent Threshold Sound Pressure Levels (ETSPLs) and, (2) real ear attenuation thresholds (REAT) for the KUDUwave earcup configured with an insert earphone using a typical immittance probe tip (TPT). Design (1) Hearing thresho
Read more
Pure-Tone Audiometry Outside A Sound Booth, Using Earphone Attenuation, Integrated Noise Monitoring, & Automation
Abstract Objective Accessibility of audiometry is hindered by the cost of sound booths and shortage of hearing health personnel. This study investigated the validity of an automated mobile diagnostic audiometer with increased attenuation and real-time noise monitoring for clinical testing outside a
Read moreSee the Kuduwave in your own practice
Book a free 30-minute online demo, or ask us anything - we usually reply within one working day.